Emission control system for a black bag waste transfer site
Issue
Exeon were asked to provide a emission control system for a black bag waste transfer site with odour and dust issues.
Solution
Exeon supplied and installed a ducted background NodourTM deep bed extraction system with extract fan and dust prefiltration handling 15,000m³/hr of flow on a 3no ACH/hr and 1.5sec contact time specification.
Project Value
£152,000